Add to Cart
3 Phase Unbalance Time Delay Undervoltage Relay Compact Modular Size
The under voltage protector is a multi-function three-phase three-wire power system or three-phase power equipment monitoring and protection equipment. Sets three-phase voltage display, over-voltage protection, under-voltage protection, phase loss protection (phase protection), three-phase voltage imbalance protection, phase sequence protection (wrong phase protection) in one. It can be used to monitor important parameters (voltage, phase sequence, phase loss, and phase balance) in three-phase power supply system. It can send alarm signals in time to abnormal conditions that may endanger the safe and reliable operation of power systems and equipment. The system can be properly handled before the machine equipment is more damaged, so that the machine equipment and system can obtain the maximum degree of protection, improve the effectiveness of the machine, equipment and system, and reduce maintenance costs due to three-phase system failures. Maintenance time. Under-voltage protectors (also called three-phase power monitor, phase sequence protector, over-voltage protector, etc.) are mainly used for AC 50/60Hz, rated voltage below 660V, industrial three-phase 100V, 220V, 380V (400V), 440V (460V), 660V and other voltage level fault detection provides relay protection for three-phase input power supply voltage is too high, voltage is too low, phase failure, wrong phase (reverse phase sequence), three-phase voltage imbalance, etc. , It can be widely used in power distribution cabinets, distribution boxes, electric control boxes, power electronic devices, telecom communication room power supplies, etc. It is an indispensable protection product that maintains normal working voltage of industrial equipment during operation.
-- Compact modular size-- Three-phase monitoring of phase sequence, phase loss, over- and undervoltage and phase unbalance-- Adjustable over- and undervoltage threshold-- Adjustable trip time
-- Powered by the measuring circuit-- 2 C/O contacts-- 5 LEDs for status indication Protective Phase sequence-- Phase loss-- Overvoltage-- Undervoltage-- Phase unbalance
♦ Typical Applications
• Pumps • Fans
• Blowers • Motors
• Compressors
♦ Approvals
• CE • CCC
♦ Technical data
Type |
JVRD-W |
Measuring circuit |
L1,L2,L3 |
Rated voltage |
220VAC,380VAC,440VAC, 460VAC,480VAC,50/60Hz |
Monitoring functions |
phase sequence,phase loss,overvoltage, undervoltage,phase unbalance |
Voltgae setting range |
±5%~±20% adjustable |
Indicators |
phase sequence,phase loss,overvoltage, undervoltage and normal |
Output contacts |
2 C/O |
Contact capacity |
6A,250VAC |
Dimensions(H*W*D) |
79*23*79mm |
Mounting |
DIN Rail |