
Add to Cart
Electronic Digital Vacuum Pressure Gauge , Absolute Pressure Gauge 304SS
Faults and Troubleshooting
The digital pressure gauge is an electromechanical product. During transportation and use, due to environmental disturbances, the improper use of human operations may cause the instrument to not work and display properly. For simple faults, users can eliminate them. Other faults need to be returned to the manufacturer for repair. The following list shows how to eliminate faults.
Symptoms Troubleshooting
No font on screen Replace battery
No change in pressure increase font Remove the battery and wait 30 seconds before reinstalling
The font is non-digital. The LCD is damaged and returned to the factory for repair.
The value is obviously inaccurate. The sensor is damaged and returned to the factory for repair.
Accuracy changes Return to factory for recalibration.
Large screen; large-screen liquid crystal display, intuitive and clear reading, adapt to wide temperature environment.High-precision; advanced microprocessor technology, imported measurement and control chip, high performance and stable accuracy.
Low power consumption; ultra-low power intelligent control, continuous use of electricity, pool for two to three years. Anti-corrosion; overall stainless steel seal structure, adapt to corrosive media environment.
High precision * Good long-term stability
* Corrosion resistance, moisture resistance * Up to three times higher overload capacity
* Easy to install * Measurable negative pressure, positive and negative pressure
* Built-in lithium battery, no external power supply
♦ Features
-- 4 digital LED display pressure, Accuracy≤0.5%
-- Three pressure units available ( Psi, Kgf/cm2 , Mpa)
-- Anti-electromagnetic interference design
-- Zero clearing with one button
♦ Typical Applications
• Machine Automation • Engineering Machinery
• Electromechanical Integration Equipment • Pump&compressor
• Hydraulic System • Medical project • Pipeline engineering
♦ Specification
Pressure range | General type:0~1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 60Mpa Micro type:0~0.2, 0.5Mpa Negative type: -0.1~0.1Mpa |
Pressure unit | MPa,kgf/cm2,PSI adjustable |
Overload pressure | 150% |
Accuracy grade | ±0.5%FS |
Power supply | 24VDC,220VAC,380VAC |
Sampling frequency | 10 times/sec |
Operating temperature | -20℃-80℃ |
Compensation Temperature | -10 ~60 ℃ |
Measurement medium | Gas, water, oil (compatible with 316 stainless steel) |
Electric protection | Short-circuit protection, reverse polarity protection, anti-electromagnetic interference design |
Pressure connector | M20*1.5 *for G1/2,G1/4 and other connector,please contact us first. |
Connector material | 304SS |
Optional module | RS485 Modbus Communication protocol |
Dial diameter | 80mm |
Shell material | ABS |
Mounting methods | Radial direction only |
Weight | 0.4Kg |