Wenzhou Ginri Power Automation Co., Ltd.

Wenzhou Ginri Power Automation Co., Ltd.

Manufacturer from China
Active Member
8 Years
Home / Products / DC Voltage Monitoring Relay /

48 Volt DC Voltage Monitoring Relay Electric control system CE / CCC Cetificayion

Contact Now
Wenzhou Ginri Power Automation Co., Ltd.
Province/State:zhejiang
Country/Region:china
Contact Now

48 Volt DC Voltage Monitoring Relay Electric control system CE / CCC Cetificayion

Ask Latest Price
Brand Name :GINRI
Model Number :DVM-A
Certification :CE CCC
Place of Origin :China
MOQ :100Pcs
Payment Terms :L/C, T/T, Western Union,Paypal
Supply Ability :20000Pcs per month
Delivery Time :1-30 days upon order quantity
Packaging Details :Relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable.
Functions :Over voltage, under voltage
Features :DC Voltage, Adjustable
Rated Voltage :DC12V DC24V DC36V DC48V
Rated Frequency :50/60Hz
Output Contacts :2C/O
Contact Capacity :5A 250VAC
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

48 Volt DC Voltage Monitoring Relay Electric control system CE / CCC Cetificayion

Overvoltage protection: When the fault voltage exceeds the protection setting value, a trip command or overvoltage signal is issued.
Low-voltage protection: When the fault voltage is lower than the protection setting value, a trip command or low-voltage signal is issued.
Overvoltage protection
Overvoltage refers to any voltage whose peak value is greater than the corresponding peak value of the maximum steady state voltage under normal operation. In engineering, it refers to any dangerous voltage that may cause damage to the equipment. Therefore, in the project, some overvoltages that are larger than the normal operating voltage but are not enough to endanger the normal operation of the equipment are excluded. Overvoltage includes:
(1) Transient overvoltage, duration of milliseconds or less, is the main protection target for lightning arresters.
(2) Transient overvoltage or short-term overvoltage, the duration is relatively long, generally between 0.1s and 1s.
The sources of transient overvoltages are: lightning strikes, switching operations, electrostatic discharges, and nuclear explosions. At the communications station, lightning overvoltages or lightning overvoltages are predominant.
Transient overvoltages mainly include: over-voltage transfer, zero-off over-voltage, over-voltage resonance over-voltage and over-voltage caused by the drift of the neutral line. In addition, capacitive effects, unbalanced ground faults, and sudden load dumps on no-load lines can also create dangerous overvoltages.

♦ Features

-- DC circuit monitoring of over and undervoltage

-- Adjustable over- and undervoltage threshold
-- Adjustable trip delay time

-- Powered by the measuring circuit

-- 1 C/O contact

-- 2 LEDs for status indication

Protective Functions

-- Overvoltage

-- Undervoltage

♦ Typical Applications

• DC cabinet • Batteries

• Electric control system

♦ Approvals

CE CCC

♦ Technical data

Type DVM-A
Measuring DC circuit
Rated voltage DC12V,DC24V,DC36V,DC48V
Monitoring functions overvoltage,undervoltage
Voltage setting range
Rated voltage Undervoltage Overvoltage
DC12V 10-14V 13-17V
DC24V 20-28V 26-34V
DC36V 30-42V 39-51V
DC48V 40-56V 52-68V
Trip delay time 1-15s adjustabel
Indicators Normal,Trip
Output contacts 2 C/O
Contact capacity 5A,250VAC
Dimensions(H*W*D) 50*40*57.5mm
Mounting plug-in

48 Volt DC Voltage Monitoring Relay Electric control system  CE  / CCC Cetificayion

Inquiry Cart 0